- 41 -
C
A
B
B
A
Possible malfuntions
Display illumination off
Machine is plugged in? (A)
Main switch on position "I"? (B)
Push in the safety button! (C)
Check the units fuse and the on-site circuit
breaker!
After 30 minutes the screen switches to
energy-saving mode
The screen is reactivated by touching the
keypad area
L.
Trouble shooting-light beam
Cut cannot be activated:
Remove all items obstructing the safety
area (A)
Only the receiver (right-hand) has a
display (B)
Green = ready for operation
Red = light beam is interrupted or error